From: patrick wintrode (pat_wde2_at_yahoo.com)
Date: Thu Mar 31 2011 - 15:01:49 CDT
Hi.
I've been testing out the new accelerated MD functionality in NAMD. I find that applying the boost just to the dihedrals works fine. However, if I use the dual boost mode, even quite small boost energies for the total-dihedral potential causes the simulation to become unstable and crash due to a constraint failure almost instantly (within ~15 steps).
My system is a 372 residue protein and the total system size protein+solvent is ~45,000 atoms.
The dihedral boost is E = 600 and alpha = 120. The smallest total-dihedral boost I've tried so far is E = 10 and alpha = 2.
Is my total-dihedral boost just too large? From reading the McCammon group's papers, it doesn't appear to be.
Any suggestions would be appreciated.
Thanks.
Patrick L. Wintrode
Assistant Professor
Dept. of Physiology & Biophysics
Case Western Reserve University
Cleveland, Ohio 44106
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2012 - 23:20:03 CST