VMD-L Mailing List
From: jeela keel (jeela22_at_gmail.com)
Date: Mon Jan 23 2012 - 11:35:59 CST
- Next message: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Previous message: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- In reply to: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- Next in thread: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Reply: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
Hi All,
I used a different dcd file that has less frames (only 263). This time it
gave same error but in the frame 262 before the last one.
is it possible that my sections are causing the problem since the measure
command is using the selections? I am selecting the protein and the
water surrounding the protein.
ERROR) measure gofr: bad frame range given. max. allowed frame#: 262
Thank you
Jeela
On Mon, Jan 23, 2012 at 12:18 PM, jeela keel <jeela22_at_gmail.com> wrote:
> yes I am doing similar way to get the number of frames.
>
> jeela
>
>
> On Mon, Jan 23, 2012 at 11:01 AM, John Stone <johns_at_ks.uiuc.edu> wrote:
>
>>
>> Are you correctly querying the number of frames with something like:
>> set number_frame [molinfo top get numframes]
>>
>> Cheers,
>> John Stone
>> vmd_at_ks.uiuc.edu
>>
>> On Mon, Jan 23, 2012 at 10:56:43AM -0500, jeela keel wrote:
>> > On Mon, Jan 23, 2012 at 10:29 AM, Axel Kohlmeyer <akohlmey_at_gmail.com
>> >
>> > wrote:
>> >
>> > isn't the error message is self-explanatory?
>> > your argument to the "last" flag is obviously incorrect.
>> >
>> > axel.
>> > >
>> > Hi Axel
>> >
>> > set gr1 [measure gofr $sel1 $sel2 delta .1 rmax 10.0 usepbc
>> > 1 selupdate 1 first 1 last $number_frame step 1]
>> >
>> > Thank you for your suggestion, I am using the last number for the
>> > frames which is 1000 frames but it stops in frame 500 and give me
>> the
>> > error
>> > jeela
>> >
>> > --
>> > Dr. Axel Kohlmeyer
>> > akohlmey_at_gmail.com http://goo.gl/1wk0
>> >
>> > College of Science and Technology
>> > Temple University, Philadelphia PA, USA.
>>
>> --
>> NIH Resource for Macromolecular Modeling and Bioinformatics
>> Beckman Institute for Advanced Science and Technology
>> University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801
>> http://www.ks.uiuc.edu/~johns/ Phone: 217-244-3349
>> http://www.ks.uiuc.edu/Research/vmd/ Fax: 217-244-6078
>>
>
>
- Next message: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Previous message: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- In reply to: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- Next in thread: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Reply: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]