VMD-L Mailing List
From: Gumbart, James C (gumbart_at_physics.gatech.edu)
Date: Thu Oct 25 2018 - 12:53:03 CDT
- Next message: Vermaas, Joshua: "RE: Pressure Control"
- Previous message: Steinar Halldorsson: "Re: AutoPSF error with glycana (end of segment error)"
- In reply to: Norge Cruz Hernández: "Pressure Control"
- Next in thread: Vermaas, Joshua: "RE: Pressure Control"
- Reply: Vermaas, Joshua: "RE: Pressure Control"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
The pressure is known to fluctuate significantly, but the algorithm is reliable. I think there are a lot of older posts on the NAMD mailing list discussing this.
Best,
JC
On Oct 23, 2018, at 10:26 AM, Norge Cruz Hernández <norge_at_us.es<mailto:norge_at_us.es>> wrote:
Hi,
I am performing an NPT simulation of the following molecular system:
- protein ( 26400 atoms)
- waters ( 9250 TIP3 molecules)
I am including in the conf file:
# Integrator and dynamics parameters
timestep 1.0
#Periodic boundary conditions
cellBasisVector1 106.936 0.0 0.0
cellBasisVector2 0.0 108.170 0.0
cellBasisVector3 0.0 0.0 107.205
cellOrigin 125.483 128.736 35.117
wrapWater on
wrapAll on
#Electrostatics with PME
PME yes
PMEGridSpacing 1.0
# Integrator and dynamics parameters
rigidTolerance 1.0e-8
timestep 1.0
switching on
switchdist 10.
cutoff 12
pairlistdist 14
stepspercycle 10
exclude scaled1-4
1-4scaling 1.0
zeromomentum on
watermodel tip3
fullElectFrequency 1
# Constant Temperature Control is off
langevin on
langevinDamping 1.0
langevinTemp 300
langevinHydrogen no
#Constant Pressure Control
langevinPiston on
langevinPistonTarget 1.01325
langevinPistonPeriod 50
langevinPistonDecay 25
langevinPistonTemp 300
useGroupPressure yes
useFlexibleCell no
useConstantArea no
# Run simulation
minimize 1000
reinitvels 300
run 5000000
After 1000 steps I have:
TOTAL: -375602.3323
TEMP: 0.0000
PRESSURE: -6730.7901
PRESSAVG: -6730.7901
Just starting the run of the dynamic, I have at step 1000:
TOTAL: -273329.7246
TEMP: 298.5816
PRESSURE: -2909.3038
PRESSAVG: -2909.3038
So, the temperature takes value of 172.4638, and it changes gradually up to 300. After 18000 I have a temperature around 195-198, which is not bad.
However, after 88000 steps I have:
TOTAL: -203037.5677
TEMP: 297.5823
PRESSURE: 87.7274
PRESSAVG: -1.0424
after 99600 steps I have:
TOTAL: -203200.5834
TEMP: 297.7877
PRESSURE: -383.3437
PRESSAVG: 3.5970
It is, the PRESSURE changes a lot step by step....
So, why do I not obtain a value of PRESSURE close to 1.01325?
Do I have to change/include some parameters in the conf file to get a value around 1.01325 for PRESSURE?
Thanks!!!
--
Prof. Norge Cruz Hernández
Dpto. Física Aplicada I
Escuela Politécnica Superior
Universidad de Sevilla
calle: Virgen de África 7,
Sevilla, Spain, E-41011
Phone number:
+34 - 954 55 01 67
+34 - 954 55 99 70
Fax number:
+34 - 954 55 43 41
Web: http://personal.us.es/norge/
[https://sic.us.es/sites/default/files/servicios/correo/Archivos/us_logo.jpg]
www.us.es<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.us.es_&d=DwMFaQ&c=OCIEmEwdEq_aNlsP4fF3gFqSN-E3mlr2t9JcDdfOZag&r=JBqQLS7jZ5whrB0hXJY8MNYcfDrh8UhlGJ2ANxoi8s0&m=XlIfhOyxGysKFVyjm3-hpDtMV5cQlXZtMbSNtT6IbP8&s=RyIsWUw1AD7ITFJ2cq-ZcX2JNozcbCgGvzH9ADEgywg&e=>
Por favor considere el medio ambiente antes de imprimir este correo electrónico.
-
Este correo electrónico y, en su caso, cualquier fichero anexo al mismo, contiene información de carácter confidencial exclusivamente dirigida a su destinatario o destinatarios. Si no es Vd. el destinatario del mensaje, le ruego lo destruya sin hacer copia digital o física, comunicando al emisor por esta misma vía la recepción del presente mensaje. Gracias