From: Axel Kohlmeyer (akohlmey_at_cmm.chem.upenn.edu)
Date: Mon Jul 30 2007 - 08:57:10 CDT

On Mon, 30 Jul 2007, sfrickenhaus wrote:

SF> Hello,

stephan,

SF> I find problems with the PBC in the gofr-gui analysis. It simply does
SF> something wrong in the vicinity of 0.75 A;

0.75A of what? please be more specific and explain (again, we all
have a short memory) how to reproduce the behavior.

SF> I set {a b c} for my mol by hand to the box dioemsnsions before.{gamma
SF> beta delta} are {90 90 90}.
SF> When I set "Update Selections" it seems OK.
SF> Any idea why this is so?

well, if you do _not_ activate 'update selections' the atom selections
are done at the very first step and then never evaluated again.
if you activate 'update selections' they are re-evaluated in every
step. this is the same behaviour as for the selection of
representations for visualization.

hope that explains it.

cheers,
   axel.