Francesco,
There are two places in the workflow where substituting MP2 geometry optimization with SCP opt + MP2 single point would matter: determining a low energy conformation of the molecule, and as input for the Hessian calculation, which I'll deal with in order. Technically speaking, the ffTK parser should handle the change in theory without a problem. You can check this by loading the optimization log and checking that VMD reads in multiple conformations into the OpenGL window. From a theoretical perspective, as long as the resulting geometry is of sufficient energy it should suffice for use in subsequent steps in the workflow, e.g., water interaction profiles. Whether this works with the Hessian calculation is less clear to me a priori, and may work for some cases but not others. The input file for the Hessian calculations tells Gaussian to read the initial coordinates from the checkpoint file output during the geometry optimization. I could imagine that an SCP-computed geometry minimum may differ from MP2 such that you would end up with problems in the frequencies. I would have to run test cases to say much more. Alternatively, if you think you have sufficient justification, you could perform all calculations as the SCP level of theory, and the ffTK parsers should continue to work (fingers crossed!).
Regards,
Christopher Mayne
On Aug 20, 2015, at 12:50 PM, Francesco Pietra wrote:
Hi Chris:
Sorry for having missed your answer. I also came across those suggestions by Gaussian, but that was not the reason. As I said it was lack of sufficient memory.
I still have to become comfortable with "divide and conquer". As it is implied in your answer that it is of such accuracy as to demand OPT/MP2, I'll try to learn how to do.
At any event, would ffTK accept the Gaussian log file from geometry optimization at SCF level, followed by single-point MP2? Or is ffTK expecting a log for geometry optimization at MP2 level?
Thanks a lot
francesco
On Thu, Aug 20, 2015 at 7:23 PM, Mayne, Christopher G <cmayne2_at_illinois.edu<mailto:cmayne2_at_illinois.edu>> wrote:
Francesco,
I responded here: http://www.ks.uiuc.edu/Research/vmd/mailing_list/vmd-l/26205.html MP2 is the level of theory prescribed by the CHARM General Force Field to accurately describe the internal dynamics of molecule. Further, it is generally accepted practice to take a "divide and conquer" approach to parameterize large ligands.
Regards,
On Aug 20, 2015, at 10:13 AM, Francesco Pietra wrote:
Hello:
I posted recently about ffTK OPT MP2 problems, no answer, however it became clear that the shared memory on a node (120GB) was not enough, and could not be increased. On the other hand, Gaussian is threaded, so that I can't exploit the enormous resources of the cluster.
Therefore, my question is, is OPT at MP2 really needed for getting a good ff for ligands along ffTK in the realm of classical MD? OPT at SCF level, followed by single-point MP2 is not enough? I understand that it depends on what one is looking for, from simple docking to normal mode calculations, so that my question covers all situations.
If SCF followed by single-point MP2 is not enough, the only alternative that I can see is to break the ligand into pieces and carry out OPT/MP2 on each piece, allowing for the approximations in reforming the whole ligand.
Thanks a lot for advice on strategy.
francesco pietra
Christopher Mayne